| 1 |
Kind of core: |
Rigid polyisocyanurate foam(PIR) |
| 2 |
Density [kg/m3]: |
p = 30 kg/m3 |
| 3 |
Declared heat transfer coefficient for lining λD: |
λD = 0,022 |
| 4 |
Type of facing: |
Double-sided cladding consisting of aluminum, paper and polyethylene. |
| 5 |
Standard board dimensions [mm]: |
600 x 1200 ; 1200 x 2400 |
| 6 |
Available boards dimensions [mm]: |
1000 x 1200 ; 1200 x 1200 ; 1800 x 1200 ; 1200 x 3000 |
| 7 |
Joint types*: |
FIT - flat milling, LAP - stepwise milling, TAG - tongue and groove |
| 8 |
Board thicknesses available [mm]: |
from 20 to 250 mm |
| 9 |
Board thickness [mm]: |
| 20 |
30 |
40 |
50 |
60 |
70 |
80 |
90 |
100 |
110 |
120 |
130 |
|
| 10 |
Thermal resistance RD: |
| 0,90 |
1,35 |
1,85 |
2,30 |
2,75 |
3,25 |
3,70 |
4,15 |
4,65 |
5,10 |
5,55 |
6,05 |
|
| 11 |
Heat transfer coefficient U for roof: |
| 0,96 |
0,67 |
0,50 |
0,41 |
0,35 |
0,29 |
0,26 |
0,23 |
0,21 |
0,19 |
0,18 |
0,16 |
|
| 12 |
Heat transfer coefficient U for wall and floor: |
| 0,93 |
0,66 |
0,50 |
0,40 |
0,34 |
0,29 |
0,26 |
0,23 |
0,21 |
0,19 |
0,17 |
0,16 |
|
| 13 |
Board thickness [mm]: |
| 140 |
150 |
160 |
170 |
180 |
190 |
200 |
210 |
220 |
230 |
240 |
250 |
|
| 14 |
Thermal resistance RD: |
| 6,50 |
6,95 |
7,45 |
7,90 |
8,35 |
8,85 |
9,30 |
9,75 |
10,2 |
10,7 |
11,1 |
11,6 |
|
| 15 |
Heat transfer coefficient U for roof: |
| 0,15 |
0,14 |
0,13 |
0,12 |
0,12 |
0,11 |
0,11 |
0,10 |
0,10 |
0,09 |
0,09 |
0,08 |
|
| 16 |
Heat transfer coefficient U for wall and floor: |
| 0,15 |
0,14 |
0,13 |
0,12 |
0,12 |
0,11 |
0,11 |
0,10 |
0,10 |
0,09 |
0,09 |
0,08 |
|
| 17 |
Reaction to fire (single board): |
20-49: F class, 50-250: E class |
| 18 |
Reaction to fire (in the system): |
B-s2,d0 (trapezoidal sheet) |
| 19 |
Broof(t1) / NRO : |
Broof(t1) (mechanism gluing) |
| 20 |
Fire resistance: |
REI 30/REI 15 (wg Fires/ITB) (od 70 mm - 250 mm) |