Specifications of the PIR Insulation Board termPIR® AL R-eco

1 Kind of core: Rigid polyisocyanurate foam(PIR)
2 Density [kg/m3]: p = 30 kg/m3
3 Declared heat transfer coefficient for lining λD: λD = 0,022​​
4 Type of facing: Double-sided cladding consisting of aluminum, paper and polyethylene.
5 Standard board dimensions [mm]: 600 x 1200 ; 1200 x 2400​​
6 Available boards dimensions [mm]: 1000 x 1200 ; 1200 x 1200 ; 1800 x 1200 ; 1200 x 3000​​
7 Joint types*: FIT - flat milling, LAP - stepwise milling, TAG - tongue and groove
8 Board thicknesses available [mm]: from 20 to 250 mm
9 Board thickness [mm]:
20 30 40 50 60 70 80 90 100 110 120 130
10 Thermal resistance RD:
0,90 1,35 1,85 2,30 2,75 3,25 3,70 4,15 4,65 5,10 5,55 6,05
11 Heat transfer coefficient U for roof:
0,96 0,67 0,50 0,41 0,35 0,29 0,26 0,23 0,21 0,19 0,18 0,16
12 Heat transfer coefficient U for wall and floor:
0,93 0,66 0,50 0,40 0,34 0,29 0,26 0,23 0,21 0,19 0,17 0,16
13 Board thickness [mm]:
140 150 160 170 180 190 200 210 220 230 240 250
14 Thermal resistance RD:
6,50 6,95 7,45 7,90 8,35 8,85 9,30 9,75 10,2 10,7 11,1 11,6
15 Heat transfer coefficient U for roof:
0,15 0,14 0,13 0,12 0,12 0,11 0,11 0,10 0,10 0,09 0,09 0,08
16 Heat transfer coefficient U for wall and floor:
0,15 0,14 0,13 0,12 0,12 0,11 0,11 0,10 0,10 0,09 0,09 0,08
17 Reaction to fire (single board): 20-49: F class, 50-250: E class
X
Send a request for contact
Your name
Your phone number
Your request was successfully sent. Our manager will contact you soon
An error occurred while sending data. Try later
X
Send a request for contact
Your name
Your phone number
Your request was successfully sent. Our manager will contact you soon
An error occurred while sending data. Try later